Call UsCall Us : 08045801877
Hard Wall Clean Rooms
Hard Wall Clean Rooms

Hard Wall Clean Rooms

MOQ : 500 Square Meters

Hard Wall Clean Rooms Specification

  • Filter Type
  • HEPA/ULPA, Pre-filter
  • Thickness
  • 50 mm and 100 mm panels available
  • Power Consumption
  • Depends on size and equipment, typically 1-3 kW
  • Filters
  • HEPA filters (Efficiency: 99.97% @ 0.3 micron); Pre filters included
  • Door
  • Swing Doors with SS/Aluminum Frame, with interlocking system
  • Condition
  • New
  • Air Flow
  • Vertical Laminar or Turbulent flow, as per design
  • Floor
  • Vinyl/PVC/ESD flooring, coving at edges for easy cleaning
  • Weight
  • Varies as per size and configuration
  • Type
  • Hard Wall Clean Room
  • Application
  • Pharmaceutical, Electronics, Biotechnology, Laboratories, Hospitals
  • Nozzle
  • Adjustable air diffusers or grilles
  • Voltage
  • 220-240 V / 50 Hz
  • Air Volume
  • Variable as per design, typical: 1500-5000 m/h
  • Material
  • Sandwich Panels with PPGI (Pre Painted Galvanized Iron) or Stainless Steel surfaces
  • Feature
  • Modular, Easy Installation & Relocation, GMP compliant, Seamless finish
  • Lighting
  • LED Flush Mount Clean Room Lighting, 350-500 Lux
  • Dimension (L*W*H)
  • Customizable as per requirements, common modules: 2m x 2m x 2.4m
  • Frame Material
  • Aluminum Extruded Section
  • Suspension System
  • Heavy-duty powder coated GI grid ceiling
  • Installation Time
  • Quick installation, typically within 2-4 days for standard modules
  • Temperature Control
  • Available with HVAC system, ±2°C variation
  • Fire Rating
  • Panels available with fire-resistant core
  • Pressure Differential
  • Monitored with magnehelic gauge, adjustable to meet specifications
  • Viewing Panels
  • Double-glazed toughened safety glass with flush mounting
  • Pass Box
  • Optional dynamic or static pass boxes with interlocking
  • Electrical Fittings
  • Modular switches, sockets, intercom provision
  • Relative Humidity Control
  • Optional; up to ±5% RH variation
  • Panel Surface Finish
  • Smooth, anti-static, easy to clean
  • Sound Insulation
  • Panels provide sound dampening for quiet operation
  • Class Range
  • ISO Class 5 to ISO Class 8 (as required)
 

Hard Wall Clean Rooms Trade Information

  • Minimum Order Quantity
  • 500 Square Meters
  • Supply Ability
  • , , Square Meter
  • Delivery Time
  • 6-8 Week
 

About Hard Wall Clean Rooms

 

Backed by our diligent employees and top notch quality raw materials, we have emerged as one of the leading manufacturers and suppliers of Hard Wall Clean Rooms. It is engineered with utmost precision and made using best in class metal alloys that we procure from reliable sources only. These rooms are widely used for making operation theaters, surgery rooms, ICUs for medical fields, etc. We have a dedicated team of quality analysts who check Hard Wall Clean Rooms on well defined quality parameters prior to dispatch. This is done to ensure that our clients get the full satisfaction and there are no complaints regarding our products.



Superior Surface and Structural Features

Hard Wall Clean Rooms are made from smooth, anti-static sandwich panels for easy cleaning and reduced dust accumulation. Double-glazed safety glass viewing panels enhance visibility while maintaining sterility, and the heavy-duty GI grid suspension ensures long-term durability. Each panel is optionally fire-rated for additional safety.


Advanced Environmental Control

Every unit offers advanced temperature management through a dedicated HVAC system with a tight 2C variation. Humidity control is available, maintaining conditions within 5% RH, making these clean rooms ideal for sensitive manufacturing and research. Pressure differentials can be precisely monitored and adjusted to ensure regulatory compliance.


Customizability and Rapid Deployment

With fully customizable dimensions to suit unique facility needs, common modules like 2m x 2m x 2.4m are readily available. Standard installations take just 24 days, minimizing downtime. Options include dynamic/static pass boxes, modular electrical fittings, and a choice of filtration systems for tailored functionality.

FAQs of Hard Wall Clean Rooms:


Q: How are Hard Wall Clean Rooms installed, and how long does the process typically take?

A: Installation is modular and streamlined, typically completed within 2 to 4 days for standard-sized modules. Panels are pre-fabricated, allowing quick assembly and minimal disruption to existing operations.

Q: What are the main benefits of using a hard wall system compared to a soft wall clean room?

A: Hard Wall Clean Rooms provide superior structural integrity, enhanced sound insulation, and a seamless finish. They offer better environmental control, are easier to clean, and can be customized to higher ISO classifications.

Q: Which industries commonly use Hard Wall Clean Rooms, and for what applications?

A: Industries such as pharmaceuticals, biotechnology, electronics, hospitals, and laboratories use these clean rooms for packaging, assembly, research, and any process requiring stringent contamination control.

Q: How does the clean room maintain precise temperature and humidity control?

A: A dedicated HVAC system regulates temperature within 2C, while optional humidity control maintains levels with a 5% RH variation. Air flow is designed as vertical laminar or turbulent according to requirements, ensuring consistency in critical operations.

Q: What options are available for pass boxes and viewing panels?

A: Clean rooms can be fitted with dynamic or static pass boxes featuring interlocking mechanisms as needed. Viewing panels are double-glazed with toughened safety glass and flush-mounted for a seamless, cleanable barrier.

Q: Are Hard Wall Clean Rooms compliant with GMP and international cleanroom standards?

A: Yes, these clean rooms are manufactured to be GMP compliant and can be tailored to meet ISO Class 5 to ISO Class 8 specifications, ensuring suitability for a range of critical applications.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Clean Room Panels Category

Modular Clean Room Panels

Modular Clean Room Panels

Price Range 1800.00 - 2400.00 INR

Minimum Order Quantity : 500 Square Meters

Type : Other , Modular Clean Room Panel

Weight : Light to Medium (varies with panel size and material)

Thickness : 50mm, 80mm, 100mm (customizable)

Condition : Other, New

Modular Walls

Modular Walls

Price Range 1800.00 - 2400.00 INR

Minimum Order Quantity : 500 Square Meters

Type : Other , Prefabricated Modular Wall Panels

Weight : 1530 kg/m depending on panel thickness and material

Thickness : 50mm, 75mm, 100mm (Customizable as per requirement)

Condition : Other, New

Clean Room Laminate panel

Clean Room Laminate panel

Price Range 1800.00 - 2400.00 INR

Minimum Order Quantity : 500 Square Meters

Type : Other , Sandwich Panel

Weight : Lightweight (varies by specification)

Thickness : 50 mm, 75 mm, 100 mm

Condition : Other, New

Hpl Panels

Hpl Panels

Price Range 1800.00 - 2400.00 INR

Minimum Order Quantity : 500 Square Meters

Type : Other , High Pressure Laminate Panel

Weight : Depends on thickness; approx. 1825 kg per sheet

Thickness : 6mm, 8mm, 10mm, 12mm, 18mm (custom sizes available)

Condition : Other, New