Call UsCall Us : 08045801877
Vertical Reverse Flow System
Vertical Reverse Flow System

Vertical Reverse Flow System

MOQ : 500 Square Meters

Vertical Reverse Flow System Specification

  • Accessories
  • Filter Bags, Duct Connection, Control Panel
  • Energy Efficiency Rating
  • High Efficiency
  • Shape
  • Rectangular
  • Air Flow Capacity
  • 2000 6000 CFM
  • Power Source
  • Electric
  • Application
  • Factories, Workshops, Manufacturing Plants
  • Humidity Range
  • 5% 95% RH
  • Mounting Type
  • Vertical Mount
  • Noise Level
  • < 65 dB
  • Motor Speed
  • 1440 rpm
  • Coverage Area
  • 100 400 m
  • Frequency
  • 50 60 Hz
  • Technology
  • Reverse Flow Filtration Technology
  • Surface Finish
  • Powder Coated
  • Material
  • Mild Steel, Stainless Steel
  • Type
  • Vertical Reverse Flow System
  • Power
  • 2.2 kW
  • Voltage
  • 220 415 V
  • Capacity
  • Up to 6000 CFM
  • Installation Type
  • Floor Mounted
  • Usage
  • Industrial Air Filtration
  • Function
  • Reverse Air Flow Filtration
  • Connection Type
  • Flanged
  • Protection Class
  • IP55
  • Service Life
  • 10+ Years
  • Discharge Type
  • Bottom or Side
  • Color
  • Grey / Custom
  • Control System
  • Digital Control Panel
  • Duct Diameter
  • 150 400 mm
  • Safety Feature
  • Overload Protection
  • Filter Efficiency
  • >99%
  • Weight
  • 450 kg
  • Dust Emission
  • <10 mg/Nm
  • Static Pressure
  • 120 350 mm WG
 

Vertical Reverse Flow System Trade Information

  • Minimum Order Quantity
  • 500 Square Meters
  • Supply Ability
  • , , Square Meter
  • Delivery Time
  • 6-8 Week
 

About Vertical Reverse Flow System

Vertical Reverse Flow Clean Air Work Station



We are involved in manufacturing of Vertical Reverse Flow Powder Containment Stations which are utilized for mixing, weighing and dispensing of powder. The offered products are well-known for their reverse flow scavenging per filter at the work level thereby ensuring that aerosolized particles are perfectly picked up at the source without allowing them dispersing into the area. Furthermore, engineered using finest quality components and raw materials with the aid of cutting-edge tools and technology, these excellent Vertical Reverse Flow Powder Containment Stations are replete with numerous quality features like stout construction, smooth workability, longer service life, minimal maintenance and excellent resistance against various detrimental effects. Apart from this, our valued customers can purchase them from us in different standard as well as customized specifications at market leading rates.

Features:

  • Chemical resistance

  • High strength

  • Durability


Further Details:



VERTICAL LAMINAR DOWNFLOW BIOLOGICAL SAFETY CABINETS

SRMC provide a unique array of Laminar Airflow Biological Safety Cabinets in compliance with the prevailing NSF/NIH/CDC and TC/ ISO guidelines and norms. We excel in the contemporary technologies in microcontamination control which enables our systems to effectively provide both biocontainment and bioexclusion .

We also manufacture cabinets of different categories if specifically ordered, such as advance design innovations for safe removal and safe exhaust of contaminated filters.

All SRMC units have the trademark of high level of professionalism, and assurance to security, full protection, high quality and value for money. Supported by advanced infrastructure, rich experienced professionals and regular research, SRMC is always focused to deliver as per the expectations of client

Technical Specification:

Tech-brief

Governing standards

ISO 14644 (1998)

Air velocity

90 fpm (0.45 mps) 20%

Cleanliness level

Fewer than 100 particles of size 0.5m or larger per cu.ft of air sampled ( or <3,520/cuM )

Noise level

< 65 dB (A Scale)

Vibration level

< 2.5m (0.0001")

Illumination level

800 lumens/ sq m (75 ft-candles) at work surface

Electricals

230V AC, 1f, 50 Hz

VERTICAL LAMINAR DOWNFLOW CLEAN AIR WORKSTATIONS
(Straddle Version)

Model

Work space dimensions

Overall dimensions

w

d

h

W

D

H

SRMC 2252-ST

24"

24"

30"

28"

30"

92"

SRMC 2253-ST

36"

24"

30"

40"

30"

92"

SRMC 2254-ST

48"

24"

30"

52"

30"

92"

SRMC 2256-ST

92"


Execution

Standard execution

Optional features

Typical applications

CRCA Powder Coated
CRCA Powder Coated work surface
Inclined tube manometer

SS execution
SS table
Dead table
UV germicidal lamp
PC side panels
PC night shutter
Air/gas cocks
Magnehelic gauge
Ultra low noise blowers

Semicon processing
Miniature assemblies
Work with open containers
Work with mildly toxic or low risk microorganisms

 

 

VERTICAL LAMINAR DOWNFLOW CLEAN AIR WORKSTATIONS
(Stand Mounted Version)

Model

Work space dimensions

Overall dimensions

w

d

h

W

D

H

SRMC 2252-SM

24"

24"

72"

28"

30"

104"

SRMC 2253-SM

36"

24"

72"

40"

30"

104"

SRMC 2254-SM

48"

24"

72"

52"

30"

104"

SRMC 2256-SM

72"

24"

72"

76"

30"

104"

 

Execution

Standard execution

Optional features

Typical applications

CRCA Powder Coated
Inclined tube manometer

SS execution
Dead table
UV germicidal lamp
PC side panels
Air/gas cocks
Magnehelic gauge
Ultra low noise blowers

Semicon processing
Ampoule filling
Vial filling
Work with open containers


 

VERTICAL LAMINAR DOWNFLOW CLEAN AIR WORKSTATIONS
(Stand Mounted Slim Version)

Model

Work space dimensions

Overall dimensions

w

d

h

W

D

H

SRMC 2252-SM-SV

24"

24"

72"

28"

50"

88"

SRMC 2253-SM-SV

36"

24"

72"

40"

50"

88"

SRMC 2254-SM-SV

48"

24"

72"

52"

50"

88"

SRMC 2256-SM-SV

72"

24"

72"

76"

50"

88"


Execution

Standard execution

Optional features

Typical applications

CRCA Powder Coated
Inclined tube manometer

SS execution
Dead table
UV germicidal lamp
PC side panels
Air/gas cocks
Magnehelic gauge
Ultra low noise blowers

Semicon processing
Ampoule filling
Vial filling
Work with open containers


VERTICAL LAMINAR DOWNFLOW CHEMICAL WET PROCESSING
CLEAN AIR WORKSTATIONS
(Straddle Version)

Model

Work space dimensions

Overall dimensions

w

d

h

W

D

H

SRMC 2253-CB-ST

36"

24"

42"

40"

50"

88"

SRMC 2254-CB-ST

48"

24"

42"

52"

50"

88"

SRMC 2256-CB-ST

72"

24"

42"

76"

50"

88"


Execution

Standard execution

Optional features

Typical applications

CRCA Powder Coated
SS work table with peripheral perforations
Acrylic side & rear panels
Front sliding sash
Inclined tube manomete

PP table
Built in sink with feed & drain fittings
Yellow lights
PC/PP side & rear panels
Exhaust ducting & flanges
Air/gas cocks
Magnehelic gauge
Ultra low noise blowers

Semicon photolithographic processing





Advanced Reverse Flow Filtration Technology

Employing reverse air flow filtration technology, this system ensures that airborne contaminants are effectively separated and collected, with filter efficiency surpassing 99%. The integrated digital control panel optimizes performance, while the robust construction and powder-coated finish provide durability in industrial environments. Its design prevents dust re-entrainment and supports demanding applications in factories and workshops.


Comprehensive Safety and Protection Features

Safety is paramount, featuring overload protection, IP55-rated enclosure, and static pressure control (120350 mm WG). The system is engineered for reliability in harsh settings and supports a wide humidity range (5%95% RH). Its flanged connections and vertical floor-mounted setup enable easy integration with existing ductwork, minimizing installation complications.

FAQs of Vertical Reverse Flow System:


Q: How does the Vertical Reverse Flow System benefit industrial air filtration processes?

A: This system utilizes advanced reverse air flow filtration technology, achieving over 99% filter efficiency and reducing dust emissions to below 10 mg/Nm. These features ensure a cleaner, safer workplace while minimizing maintenance requirements and energy costs.

Q: What are the installation requirements for the Vertical Reverse Flow System?

A: The system is designed for vertical, floor-mounted installation, with flanged connections suitable for duct diameters ranging from 150 to 400 mm. It accommodates bottom or side discharge and covers areas from 100 to 400 m, making it adaptable to various factory and workshop spaces.

Q: When should the filter bags and duct connections be serviced or replaced?

A: Routine inspection is recommended every six months, but actual servicing intervals depend on dust load and operating conditions. Thanks to the systems >99% filter efficiency, filter bags have an extended service life, usually only requiring replacement after considerable use, typically within the systems ten-year lifespan.

Q: Where is the Vertical Reverse Flow System best suited for application?

A: It is ideal for industrial settings like manufacturing plants, factories, and workshops requiring efficient air filtration. Its versatility in duct connection and discharge type suits diverse operational layouts and demanding environments.

Q: What is the process for controlling and monitoring the systems operation?

A: Operation and monitoring are managed by a digital control panel, which allows users to adjust static pressure, motor speed, and monitor system performance. This automation ensures continuous high efficiency and reliable functioning.

Q: How does the overload protection feature enhance system safety?

A: Overload protection safeguards the motor and electrical components by automatically detecting excessive loads and preventing damage. This ensures uninterrupted operation and longer service life, especially in intensive industrial applications.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Laminar Air Flow Systems Category

Laminar Air Flow Cabinet

Laminar Air Flow Cabinet

Price Range 1800.00 - 2400.00 INR

Minimum Order Quantity : 500 Square Meters

Usage : Other, Laboratories, Research Facilities

Shape : Rectangular

Air Flow Capacity : 90 FPM (Feet Per Minute)

Function : Other, Air Purification & Particle Filtration

Horizontal Laminar Air Flow Cabinet

Horizontal Laminar Air Flow Cabinet

Price Range 1800.00 - 2400.00 INR

Minimum Order Quantity : 500 Square Meters

Usage : Other, Laboratory/Industrial Clean Room

Shape : Rectangular

Air Flow Capacity : 9001200 m3/h (Customizable)

Function : Other, Airborne Particle Removal

Laminar Air Flow

Laminar Air Flow

Price Range 1800.00 - 2400.00 INR

Minimum Order Quantity : 500 Square Meters

Usage : Other, Laboratory, Research, Hospital

Shape : Rectangular

Air Flow Capacity : 0.3 to 1.0 m/s

Function : Other, Air Filtration & Clean Air Supply